PLC-XU300/350 Expand Serial Command Functional Specifications37 / 66This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.18 CF_KEYDIS CommandCommand “CF_KEYDIS_%1”[CR]%1“NONE” ----------------------- RC & Projector keys are valid (All are valid)“RC” ---------------------------- RC keys are invalid“KEY” -------------------------- Projector keys are invalidDetails Diable RC/Projector keysThis command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.19 CF_PJPINCODE CommandCommand “CF_PJPINCODE_%1”[CR]%1 “0000” – “9999” ---------Set PJ PIN CODE directlyDetailsSet PJ PIN CODE to release PJ LOCK.PIN CODE cannot be changed by this command.-When PJ LOCK is in operationPIN CODE is correct ------------------------- Command is valid (Acceptable)PIN CODE is incorrect ----------------------- Command is invalid(Error Code”102”)PIN CODE is out of %1 range ------------- Command is invalid (Error Code “? “)-When PJ LOCK is not in operationPIN CODE is within %1 range ---------------- Command is valid (Acceptable)PIN CODE is out of %1 range ---------------- Command is invalid (Error Code “? “)This command is valid during a dialog “PJ PIN CODE” is displayed after Power Onand Count down.Also when PJ LOCK setting is “On1”, it is necessary to transmit this commandeverytime lamp turns on.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.20 CF_FANMODE CommandCommand “CF_FANMODE_%1”[CR]%1 “L1” ---------------------------- Set Fan Mode to L1“L2” ---------------------------- Set Fan Mode to L2DetailsSwitch Fan ModeWhen L1 is selected, fan noise after POWER OFF is louder.When L2 is selected, fan noise after POWER OFF becomes quiet, however, fanrotates longer than L1.The status set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]