PLC-XU300/350 Expand Serial Command Functional Specifications38 / 668.10.21 CF_FANCONTROL CommandCommand “CF_FANCONTROL_%1”[CR]%1“OFF” ---------------------------- Set Fan control to Off“ON1” ---------------------------- Set Fan control to On1“ON2” ---------------------------- Set Fan control to On2“ON3” ---------------------------- Set Fan control to On3DetailsSet Fan control setting.The status set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.22 CF_CCAPTIONDISP CommandCommand “CF_CCAPTIONDISP_%1”[CR]%1“OFF” ------------- Select Off“CC1” ------------- Select CC1“CC2” ------------- Select CC2“CC3” ------------- Select CC3“CC4” ------------- Select CC4DetailsSelect channel of Closed caption.The status set with this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Closed caption is available under conditions below;Entered signal is appropriate (Video, NTSC signal of S-video, Component=480i)and System is fixed to NTSC or 480i.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.23 CF_CCAPTIONCOLOR CommandCommand “CF_CCAPTIONCOLOR_%1”[CR]%1 “COLOR” ------- Select Color“WHITE” -------- Select WhiteDetailsSelect color of Closed caption.The status set with this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Closed caption is available under conditions below;Entered signal is appropriate (Video, NTSC signal of S-video, Component=480i)and System is fixed to NTSC or 480i.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.24 CF_FILTIMER CommandCommand “CF_FILTIMER_%1”[CR]%1“100” -------------------- Set 100 hours“200” -------------------- Set 200 hours“300” -------------------- Set 300 hours“OFF” ------------------- No warning display“UP” --------------------- Switch Filter timer forwardOff →100 → 200 → 300 → Off“DN” --------------------- Switch Filter timer backwardOff → 300 → 200 → 100