TB9300 Installation and Operation Manual Installation 75© Tait Limited March 20165.3 Identifying the EquipmentYou can identify the model and hardware configuration of the TB9300modules by referring to the product code printed on labels at the rear ofeach module. The meaning of each character in the product code isexplained in the tables below.This explanation of product codes is not intended to suggest that anycombination of features is necessarily available in any one product.Consult your regional Tait office for more information regarding theavailability of specific models and options.Reciter ProductCodesPA Product CodesProduct Code DescriptionT01-01105-XXXX Frequency BandC = 136MHz to 156MHzD = 148MHz to 174MHzH = 330MHz to 380MHzK = 400MHz to 440MHzL = 440MHz to 480MHzM = 470MHz to 520MHzR = 400MHz to 440MHz (receive)R = 440MHz to 480MHz (transmit)N = 762 MHz to 870MHz aQ = 896MHz to 902MHz (receive)Q = 927MHz to 941MHz (transmit)a. The actual frequency coverage in this band is:Transmit: 762MHz to 776MHz and 850MHz to 870MHzReceive: 792MHz to 824MHzTait Band IdentifierB2 bandB3 bandG4 bandH1 bandH2 bandH3 bandHC bandHC bandK4 bandL2 bandL2 bandT01-01105-XXXX A = standardT01-01105-XXXX A = defaultT01-01105-XXXX A = defaultProduct Code DescriptionT01-01136-XXXX Frequency BandC = 136MHz to 174MHzH = 330 MHz to 380 MHzJ = 380MHz to 520MHzN = 762MHz to 870MHz aQ = 850MHz to 941MHza. The actual frequency coverage in this band when used with a K-band TB9300 re-citer is 762MHz to 776MHz and 850MHZ to 870MHz.Tait Band IdentifierB1 bandG4 bandH0 bandK2 bandL0 bandT01-01136-XXXX A = 50WB = 100WT01-01136-XXXX A = defaultT01-01136-XXXX A = default