4 – Operation : Writing Switch EventsTASCAM DM Automation Guide 25Disabling Auto Revert allows you to stop writingswitch events manually, either by stopping the time-code or by pressing the REVERT key. In this case, allcontrols that are writing will stop writing simulta-neously when REVERT is pressed or when timecodestops.See the diagram below to understand this behavior:Figure 22: Writing new switch events over previous switch events with Auto Revert disabled8 sec8 sec8 sec1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 secExisting Switch EventsNew Switch EventsResulting Switch EventsSwitch ONSwitch ONSwitch ON Switch ONSwitch ONSwitch OFFSwitch OFFSwitch OFFPress REVERTSwitch OFF