June 2022 Service and Repair ManualDeutz D 2.9 L4 Engine Fault CodesPart No. 1268555GT Z ®-62/40 117SPN = Suspect Parameter NumberFMI = Failure Mode IdentifierKWP = Keyword ProtocolSPN FMI KWP Description523605 9 300 Timeout Error of CAN-Receive-Frame TSC1AE; TractionControl523606 9 301 Timeout Error of CAN-Receive-Frame TSC1AR; Retarder523612 12 387 Internal software error ECU;injection cut off523612 12 612 Internal ECU monitoringdetection reported error523612 12 613 Internal ECU monitoringdetection reported error523612 12 614 Internal ECU monitoringdetection reported error523612 12 615 Internal ECU monitoringdetection reported error523612 12 616 Internal ECU monitoringdetection reported error523612 12 617 Internal ECU monitoringdetection reported error523612 12 618 Internal ECU monitoringdetection reported error523612 12 619 Internal ECU monitoringdetection reported error523612 12 620 Internal ECU monitoringdetection reported error523612 12 621 Internal ECU monitoringdetection reported error523612 12 623 Internal ECU monitoringdetection reported error523612 12 624 Internal ECU monitoringdetection reported error523612 12 625 Internal ECU monitoringdetection reported error523612 12 627 Internal ECU monitoringdetection reported error523612 12 628 Internal ECU monitoringdetection reported errorSPN FMI KWP Description523612 12 637 Internal ECU monitoringdetection reported error523612 12 1170 Internal software error ECU523612 14 973 Softwarereset CPU SWReset_0523612 14 974 Softwarereset CPU SWReset_1523612 14 975 Softwarereset CPU SWReset_2523613 0 856 Maximum positive deviation ofrail pressure exceeded(RailMeUn0)523613 0 857 Maximum positive deviation ofrail pressure in metering unitexceeded (RailMeUn1)523613 0 858 Railsystem leakage detected(RailMeUn10)523613 0 859 Maximum negative deviation ofrail pressure in metering unitexceeded (RailMeUn2)523613 0 860 Negative deviation of railpressure second stage(RailMeUn22)523613 0 862 Maximum rail pressureexceeded (RailMeUn4)523613 1 861 Minimum rail pressure exceeded(RailMeUn3)523613 2 864 Setpoint of metering unit inoverrun mode not plausible523615 3 594 Metering unit (Fuel-System);short circuit to battery highside523615 3 596 Metering unit (Fuel-System);short circuit to battery low side523615 4 595 Metering unit (Fuel-System);short circuit to ground high side523615 4 597 Metering Unit (Fuel-System);short circuit to ground low side523615 5 592 Metering unit (Fuel-System);open load523615 12 593 Metering unit (Fuel-System);powerstage over temperature523619 2 488 Physical range check high forexhaust gas temperatureupstrem (SCR-CAT)523698 11 122 Shut off request fromsupervisory monitoring function