Operator's Manual Eighth Edition • First PrintingInspections28 Z ® -30/20N • Z ® -30/20N RJ Part No. 1319005GTAt the Ground Controls1 Select a test area that is firm, level and free ofhazards.2 Turn the key switch to ground control.3 Pull out the red Emergency Stop button to theon position.Result: The beacon (if equipped) should flash.Test Emergency Stop4 Push in the ground red Emergency Stopbutton to the off position.Result: No functions should operate.5 Pull out the red Emergency Stop button to theon position.Test the Boom Functions6 Do not hold the function enableswitch to either side. Attempt toactivate each boom and platformfunction toggle switch.Result: No boom and platform functionsshould operate.7 Hold the function enable switch to either sideand activate each boom and platform functiontoggle switch.Result: All boom and platform functions shouldoperate through a full cycle.Test the Tilt Sensor8 Turn the key switch toplatform control. Pull out theplatform red EmergencyStop button to the onposition.9 Open the control panel sideturntable cover and locatethe tilt sensor next to thefunction manifold.10 Press down one side of the tilt sensor.Result: The alarm, located in the platform,should sound.Test Auxiliary Power11 Turn the key switch to ground control.12 Pull out the red Emergency Stop button to theon position.13 Simultaneously hold the auxiliarypower switch on and activate eachboom function toggle switch.Note: To conserve battery power, test eachfunction through a partial cycle.Result: All boom functions should operate.