SafetyInstallation and maintenance instructions ecoTEC exclusive 0020017768_07 933.4 General requirements3.4.1 Preliminary remarksThis appliance must only be installed and commissionedby a suitably competent person. Please check with yourinstaller that he is able to carry out all the necessaryworks including official notification of the works to therelevant body upon completion.3.4.2 Related documentsThe installation of the appliance and any associated hotwater system must be in accordance with (but not lim-ited to) the following; COSHH regulations, Gas Safety(Installation and Use) Regulations 1998, Health andSafety Document No. 635 (The Electricity at Work Regu-lations 1989), BS7671 (IEE Wiring Regulations) and theWater Supply (Water Fitting) Regulations 1999, or TheWater Bylaws 2000 (Scotland). It should also be inaccordance with the relevant requirements of the LocalAuthority, Building Regulations, The Building Regulations(Scotland), The Building Regulations (Northern Ireland)and the relevant recommendations of the following Brit-ish Standards:BS 6700: Services supplying water for domestic usewithin buildings and their curtilages.BS 6798: Specification for installation of gas fired boil-ers not exceeding 60 kW input.BS 6891: Specification for installation of low pressuregas pipework up to 28 mm (R1) in domestic premises(2nd family gas).BS 7593: Treatment of water in domestic hot water cen-tral heating systems.Institute of Gas Engineers Publication IGE/UP/7/1998:”Guide for gas installations in timber framed housing”BS. 5482 Pt. 1 Domestic butane and propane gas burn-ing installations.IGE/UP1 Soundness testing and purging of industrialand commercial gas installation.IGE/UP2 Gas installation pipework, boosters and com-pressors on industrial and commercial premises.IGE/UP10 Installation of gas appliances in industrial andcommercial premises.BS. 6644: Installation of gas fired hot water boilers ofrated inputs between 60 kW and 2 MW (2nd and 3rdfamily gases).BS. 5449: Forced circulation hot water central heatingsystems for domestic premises. Note: only up to 45 kW.BS. 6880: Low temperature hot water heating systemsof output greater than 45 kW.Part 1 Fundamental and design considerations.Part 2 Selection of equipment.Part 3 Installation, commissioning and maintenance.BS. 4814: Specification for: Expansion vessels using aninternal diaphragm, for sealed hot water heating sys-tems.BS. 5440: Installation and maintenance of flues andventilation for gas appliances of rated input not exceed-ing 70 kW net (1st, 2nd and 3rd family gases).Part 1 Specification for installation of flues.Part 2 Specification for installation and maintenance ofventilation for gas appliances.