Adapting the appliance to the heating system76 Installation instructions geoTHERM 0020051574_0499.7.1 Menu C: Set parameters for the heatingsystemDisplay shown Description Factory settingMenu C: Set parameters for the heatingsystemYou can set parameters for the various functions ofthe heat pump in the menus C1 to C11.Code level C1changeCode number:> 0 0 0 0Accept change? no>Adjust numeric characterMenu for changing the code number.You can replace the standard code 1000with a user-defined four-digit code here.i If you change the code, make a note of thenew code, otherwise you will no longer beable to make changes in the Code level.1000HK2 C2ParametersType Direct circuitHeating curve 0,30Max. limit outs.temp. >20 °CComp. starts at -120° min>Select temperature HK2 C2ParametersMax. limit outs.temp. >20 °CComp. starts at -120° minMinimum temperature 15 °CMaximum temperature 43 °C>Select temperatureIf a VR 60 is connected, this menu appears severaltimes (for each heating circuit).Type: Direct circuit (for direct hydraulic systems),Mixed circuit (for buffered hydraulic systems),Fixed value.Heating curve: Adjustable heating curve (not withfixed value).Max limit outs.temp.: Temperature threshold forswitching off Heating mode (summer function).Comp.starts at: Set the degree minutes until com-pressor start (only with direct hydraulics).Minimum/maximum flow temp.: Setting the limitingtemperatures (min. and max.) that the heatingcircuit can request.The maximum flow temperature is also used tocalculate the value for the underfloor protectivecircuit (maximum HC temperature + compressorhysteresis + 2 K).If the mixed circuit heating circuit type is set,the underfloor protective circuit is disabled andthe factory setting is 50 °C.Heating curve: The heating curve represents therelation between the outside temperature andtarget flow temperature. The setting is madeseparately for each heating circuit.The efficiency and convenient operation of theheating system significantly depend on theselection of the correct heating curve. If toohigh a heating curve is selected, the tempera-ture in the heating system will be excessive and,as a result, energy consumption will be higher. Ifthe selected heating curve is too low, thedesired temperature level may only be reachedafter a while or not reached at all.0,320 °C15 °C43 °C9.6 Menu C: Set parameters for the heating system