GAS CONSUMPTIONNatural GasHas a maximum natural gas input of 5.7kW (Gross)Has a maximum natural gas output of 4.31kWHas a minimum natural gas input of 2.0kW (Gross)Has a minimum natural gas output of 1.33kWLPGHas a maximum LPG input of 5.6kW (Gross)Has a maximum LPG gas output of 4.23kWHas a minimum LPG gas input of 3.3kW (Gross)Has a minimum LPG gas output of 2.37kWOPERATING YOUR FIREThe Oxysafe flame sensing and flue blockage safety system.For your safety, this appliance is fitted with a flue blockage safety device which willshut down the appliance in the event of abnormal flue conditions. This device isNOT a substitute for an independently mounted Carbon Monoxide detector.The device will also automatically shut off the gas supply to the fire if the pilot flamegoes out due to lack of oxygen or for any other reason.If this device starts to repeatedly shut off the gas, get expert advice.This device incorporates a probe which senses that the heat from the pilot flame iscorrect. If this probe is cool, the device will prevent any gas flow unless the controlknob is held in at the ignition position.If, for any reason, the flames go out when the fire is hot or if the fire is turned offwhen hot, always wait at least three minutes before attempting to relight.Pa ge 4 8© Baxi Heating U.K. Limited 2007.OWNER GUIDEPLEASE NOTEWhen operating your fire for the first time, some vapours may be given off which maycause a slight odour and could possibly set off any smoke alarms in the immediatevicinity. These vapours are quite normal with new appliances. They are totally harmlessand will disappear after a few hours use.