Operating the fire WITHOUT the Remote Control Handset.Lighting the burner in the event of battery failure.1. To gain access to the gas valve it will be necessary to remove the fascia. Thebottom of the fascia is held in place with magnets. Hold the lower outside edges ofthe fascia and gently pull forward. With the bottom released, lift the fascia upward andclear of the upper hanging brackets on the convection box.2. The ‘main valve knob’ is the knob on the right hand side (See figure 5). Turn thisknob to the ‘OFF’, fully clockwiseposition .3. The ‘manual knob’ is the knob onthe left hand side (See figure 5).Turn this knob to the ‘OFF’, fullyclockwise position.4. Place the ‘ON/OFF’ switch to the‘O’ (Off position).5. Wait five (5) minutes to clear outany gas. Then smell for gas,including near the floor. If you smellgas STOP! and follow the safetyinformation below. DON’T SMOKE. EXTINGUISH ALL NAKED FLAMES. DON’T TURN ELECTRICAL SWITCHES ON OR OFF. TURN OFF THE GAS SUPPLY AT THE METER OR TANK AS APPROPRIATE. OPEN DOORS AND WINDOWS TO GET RID OF THE GAS. IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A NEIGHBOURSPHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY.If you do not smell gas, proceed as below.6. Place the ‘ON/OFF switch to the ‘- ’ (On position).7. With the ‘manual’ knob in ‘MAN’ position a manualpilot valve operator is accessible (See figure 6). Fully push down the manual pilot valveoperator using the end of a pencil or similarand hold in to start pilot gas flow. Immediatelylight the pilot with a long match held at 45° atthe left hand side of the pilot (See figure 7),while continuing to hold in the manual pilotvalve operator for about ten (10) secondsafter the pilot is lit. Release manual pilot valveoperator. If pilot does not stay lit, repeat steps2 through 7.OWNER GUIDE© Baxi Heating U.K. Limited 2009. Page 49Figure 6. Pilot valve operatorFigure 5. Controls