6. IGNITION CHECKBefore attempting to install, it is worth checking that the electronic ignition systemperforms satisfactorily.Fit the battery to the ignition block located below theburner tray at the left side (See figure 10). Thelocations for the +ve and -ve terminals are marked onthe battery holder.Rotate the control pivot bracket clockwise as far as itwill go and hold in this position (See figure 11). Thisshould close the ignition circuit and sparks should beseen tracking from the electrode pin to the pilot tip(See figure 11).If there are no sparksmake the followingchecks. Check condition ofbattery and that it iscorrectly fitted. If the above issatisfactory, check theignition circuit andcomponents - seesection 17 which is the servicing and parts replacement section in this guide.7. GAS SUPPLY CONNECTIONA nut and olive are provided for an 8mm pipe inlet connection to the ‘T’ connector atthe bottom front of the appliance. The ‘T’ connector can be rotated to allow aconnection from any direction and includes a valve for isolating the gas supply and apressure test point.The supply pipe must be rigid material. Flexible pipe must not be used.Concealed Supply Pipe Connection.If a concealed connection from inside the fireplace is required then, before theappliance is fitted into the fireplace it will be necessary to extend the supply line sothat it will project through the hole in the back of the convection box and run to the ‘T’connector at the front. The pipe run from the supply line up to the rear opening in theconvection box must be kept away from the area which will be taken by theconvection box when it is installed (See figure 6).Note that the centre of the appliance inlet ‘T’ connector is 25mm above the fireplacefloor. The inlet ‘T’ connector should be fitted to the supply pipe at this stage.Page 24© Baxi Heating U.K. Limited 2009.INSTALLER GUIDEFigure 11. Slider controlFigure 10. Fitting the battery