13. FITTING THE CERAMIC FUEL EFFECTThe installer and owner guide for the ceramic fuel effect is supplied with the ceramicfuel effect. It is important that the fitting guide for the ceramic fuel effect be placedinside or attached to this guide and handed to the customer following completion ofthe ‘Final review’ section.Ensure that the fire is OFF. Open the isolating valve at the inlet ‘T’ connector andreplace the end cap. Light the fire, turn to the maximum output position and testaround the sealing screw for gas soundness with a suitable leak detection fluid.14. FIREFRONT / BOTTOM COVER INSTALLATION14.1 Adorn bottom front cover.Place the bottom front cover in position below the fascia bridge.14.2 Visage, Obsession and Eternal fire front casting.14.2.1 Fit the fire front casting to the fascia. Locate the two screw heads at the reartop corners of the firefront casting through the keyhole slots at the inner sides of thefascia. If the screw heads do not projectenough or project too far, the screws can beadjusted. Lower the casting so that it rests onthe hearth (See figure 41).14.2.2 (Obsession and Eternal only) Place thebottom front cover casting in position below thefire front casting.14.3 Icon bottom front cover.Locate the top flanges of the bottom front coverbehind the bottom edge of the fascia. Fix thesides of the cover to the fascia bottom cornerbrackets with the twoknurled screwsprovided (See figure42).Page 37© Baxi Heating U.K. Limited 2009.Figure 42. Icon bottom front cover location.INSTALLER GUIDEFigure 41. Firefront casting (Castingmay differ from that shown).