7611 SupplementVEGAPULS 63 • Modbus and Levelmaster protocol41364-EN-170711Ambient conditionsAmbient, storage and transport tempera-ture-40 … +80 °C (-40 … +176 °F)Process conditionsThe following specifications are for information. The specifications on the type plate must be noted.Process temperatureAntenna encapsulation Version Process temperature (measured on the processfitting)PTFE and PTFE 8 mm Standard -40 … +200 °C (-40 … +392 °F)Low temperature -196 … +200 °C (-321 … +392 °F)TFM-PTFE and TFM-PT-FE 8 mmStandard -40 … +150 °C (-40 … +302 °F)TFM-PTFE 8 mm Flange Alloy 400 (2.4360) -10 … +150 °C (14 … +302 °F)PTFE Additional process seal,FKM-20 … +130 °C (-4 … +266 °F)Additional process seal,EPDM-40 … +130 °C (-40 … +266 °F)PFA and PFA 8 mm Standard -40 … +150 °C (14 … +302 °F)High temperature -40 … +200 °C (-40 … +392 °F)Vessel pressureVersion Process fitting, pressurestageVessel pressureStandard (PTFE and PFA) Flange PN 6 -1 … 6 bar (-100 … 600 kPa/-14.5 … 87 psig)Flange PN 10 (150 lb) -1 … 10 bar (-100 … 1000 kPa/-14.5 … 145 psig)Flange PN 16 (300 lb),PN 40 (600 lb)-1 … 16 bar (-100 … 1600 kPa/-14.5 … 232 psig)Tieftemperature version upto -196 °C (-321 °F)Flange DN 50, DN 80PN 16, PN 402", 3" 300 lb 600 lb-1 … 20 bar (-100 … 2000 kPa/-14.5 … 290 psig)Hygienic SMS -1 … 6 bar (-100 … 600 kPa/-14.5 … 87 psig)VariventClamp 3", 3½", 4" PN 10PN 16-1 … 10 bar (-100 … 1000 kPa/-14.5 … 145 psig)Remaining hygienic fittings -1 … 16 bar (-100 … 1600 kPa/-14.5 … 232 psig)Vibration resistance 4 g at 5 … 200 Hz according to EN 60068-2-6 (vibrationwith resonance)Shock resistance 100 g, 6 ms according to EN 60068-2-27 (mechanicalshock)