Mobile Generators Factory-Installed Optionswc_tx000380gb.fm 795.6 Lube Level MaintainerSee Graphic: wc_gr001711, wc_gr001712, wc_gr001713The lube level maintainer system protects the engine from low oillevels by providing an additional 6-quart oil reservoir. Oil from thereservoir is gravity-fed from the oil reservoir (a) through the controlvalve (b) and into the engine oil pan as needed. The valve includes asightglass (c) through which the oil level can be seen. This oil level isthe same as that measured by the engine dipstick. A float inside thevalve detects low oil levels and opens the valve to supply the neededoil. The system is wired to the ECM and includes a low oil shutdown incase the oil in the reservoir is depleted. If the engine shuts down dueto low oil, the ECM will display “FAULT LOW OIL LEVEL”. Fill theengine and the additional oil reservoir with oil before placing thegenerator back into service.Note: On machines with the Isuzu engine, the reservoir is mounted tothe enclosure door.NOTICE: To prevent overfilling the engine with oil, place the shutoffvalve (d) in the closed position when moving or towing the generator.Once the generator is in position, open the valve.