GPi 3200 / 4300 Operationwc_tx001239gb.fm 312.14 Before StartingExplanation Before putting the generator into service, review each item on the followingchecklist. It is important to make sure that the machine is set up properly to reducethe possibility of malfunction.Before starting the generator:Exteriorchecks check for damage that may have occurred during towing or travel to the jobsite check for fuel leaks check for loose or missing fasteners make sure the exhaust pipe is not clogged with debris make sure that the generator is level make sure the generator is not resting on against any adjacent wiring make sure that the generator air vents are not blocked make sure that the generator is grounded to a good earthen ground per localregulations and NEC standardsInternal andpre-operationchecks check engine oil and fuel levels—fill as required determine voltage needs review and follow safety instructions found in the front of this Operator’s ManualDANGERCarbon monoxide. Using a generator indoors CAN KILL YOU IN MINUTES.Generator exhaust contains carbon monoxide (CO). This is a poison you cannotsee or smell. If you can smell the generator exhaust, you are breathing CO. Buteven if you cannot smell the exhaust, you could be breathing CO.WARNINGPersonal injury hazard. Failure to follow the listed procedures may cause injury topersonnel or damage to the generator.f Make sure that all persons setting up the generator are certified or fully trainedon the installation and operation of the generator.