Operation GPi 3200 / 430036 wc_tx001239gb.fmConnectingand charginga batteryFollow the procedure below to connect and charge a battery.1. Connect the positive terminal (e1) (red) on the generator to the positive (+)battery terminal.2. Connect the negative terminal (e2) (black) on the generator to the negative (-)battery terminal.3. Charge the battery for the recommended length of time prescribed by thebattery manufacturer.Disconnectingthe batteryWhen the battery is fully charged:1. Disconnect the cable from the negative (-) terminals of the battery and the generator.2. Disconnect the cable from the positive (+) terminals of the battery and the generator.If the DCcircuit breakeractivatesThe DC circuit breaker (f) may activate while a battery is charging. This may occurfor either of the following reasons: Defective battery—check the battery before replacing the DC breaker Excessive current draw from a large capacity battery or a totally dischargedbattery—use an AC battery charger to charge the battery instead of the generator.2.19 Stopping the GeneratorBeforestoppingInform other personnel on the jobsite that power is being turned off. Make sure thatthe power shutdown will not create any hazards by turning off devices such aspumps, heaters, or lights that may need to be kept on.StoppingprocedureTo stop the generator:1. Switch off and disconnect all equipment from the generator.2. Allow the generator to run at no load for approximately 3 minutes.3. Turn the engine switch (h) to the STOP position.4. (Electric start models only): Turn the key switch (g) to the “O” (STOP) position.wc_gr006678hg