Operation GPi 3200 / 430032 wc_tx001239gb.fm2.15 Starting the Generator (S Models)StartingprocedureFollow the procedure below to start the machine.1. Turn the engine switch (h) to the CHOKE position (or the RUN position if theengine is warm or the ambient temperature is high).2. Insert the starting key into the key switch (g).3. Turn the starting key clockwise to the “I” (ON) position, then farther to theSTART position. The engine will start.NOTICE: To avoid machine damage, do not engage the starter motor continuouslyfor more than five seconds. If the engine fails to start, return the starting key to theON position, wait approximately 10 seconds, and then try again.Do not turn the key switch to the START position when the engine is running.4. If you started the engine with the engine switch in the CHOKE position, allow theengine to run for 20–30 seconds and then turn the engine switch to the RUNposition.5. Use the LED changeover switch (n) to switch to display voltage on the LCD. Areading of 120V indicates that the generator is operating properly.Troubleshooting If the engine does not start after several attempts, repeat the starting procedurewith the engine switch turned to the RUN position. Try starting the machine manually. See Starting the Generator (Manual StartModels). If the engine still does not start, refer to the Troubleshooting chapter.CAUTIONPersonal injury or machine damage hazards. Starting the generator with equipmentattached can damage the generator or the equipment. Unexpected equipmentstart-up can cause personal injury.f Disconnect all equpment from the generator before starting it.wc_gr006666hng