! WARNING: Do not pack required air space (clearance) with insulation or other materials. When non-combustible building materials contact the body of the oven, the clearances to combustibles aretransferred to those non-combustibles.! WARNING: Installation and servicing of this product could expose you to glasswool/ceramic fibers as well ascalcium silicate dust� ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING OR SERVICINGTHIS APPLIANCE� Please read this entire manual before you install the oven� Failure to follow instructionsmay result in property damage, bodily injury or even death� Contact your local building or fire officials aboutrestrictions and installation inspection in your area�CLEARANCESa. The Wood Stone Phoenix oven must have a minimum 25 mm (1") clearance to combustibles from all sides, 152 mm(6") clearance to combustibles from the top and 152 mm (6") from the flue collar. If building a facade that will contactthe oven, use completely non-combustible materials� Any facade wall built 152 mm (6") to either side of the doorway orabove must be of non-combustible construction� Please note that standard Drywall (or Sheetrock) is considered a limitedcombustible� Any walls perpendicular to the front of the oven in the area 762 mm (30") to either side of the doorway and 914mm (36") in front of the oven should have a non-combustible surface�b. The oven must be installed on a non-combustible floor surface� The non-combustible floor surface must extend 914 mm(36") in front of and 914 mm (30") to either side of the oven doorway�Maintain 152 mm(6") clearance fromthe flue outlet Ruled area (152 mm(6") to either side ofdoorway and above)represents space wherefacade materials mustbe non-combustible.Hatched area mustbe left accessibleand unobstructedafter installation forair intake and routineservice of the ovenburner.25 mm (1")minimum sideclearance tocombustibleconstructionNon-combustiblefloor, 914 mm (36")in front and 762(30") mmto either side ofoven doorway8An ongoing program of product improvement may require us to changespecifications without notice. BL-RFG-CE, BL-RFG-W-CE,Revised February 2015. Doc no: M0027.02info@woodstone-corp.com or visit woodstone-corp.comwood stone corporation1801 w. bakerview rd.bellingham, wa 98226 usat. +1.360.650.1111f. +1.360.650.1166Bistro CE Installation and Operation ManualINSTALLATION CLEARANCESINSTALLATION CLEARANCES