08/20122-57WorkCentre 5021/5019 2.2.3.1, 2.2.3.2Status Indicator RAPsInitial Issue2.2.3.1 AC Power FIPBSD-ON:CH1.1ProcedureTurn OFF the Main Power Switch. Is the voltage between the Main Power Switch J3 andJ4 120VAC/220 to 240VAC?Y NIs the voltage between the AC Inlet J1 and J2 120VAC/220 to 240VAC?Y NUnplug the Power Cord from the outlet. Is 120VAC/220 to 240VAC measured atthe outlet?Y NCheck the customer's Breaker, etc.Check the Power Cord for open circuit and poor contact. If no problems are found,replace the AC Inlet. (PL 18.1)Check the connections between the AC Inlet J1, J2 and the Main Power Switch J3, J4for open circuits and poor contacts.Turn ON the Main Power Switch. Is the voltage between the LVPS J510-1 and J510-3120VAC/220 to 240VAC?Y NTurn OFF the power and unplug the Power Cord from the outlet.- LVPS [120VAC] -Check the connections between the Main Power Switch J5, J6 and the LVPS J510 pin-1 and pin-2 for open circuits and poor contacts.- LVPS [220VAC] -Check the connections between the Main Power Switch J5, J6 and the LVPS J510 pin-1 and pin-3 for open circuits and poor contacts.If no problems are found, replace the Main Power Switch. (PL 18.1)Check the AC circuit to each component by referring to Chapter 7 Wiring Data.2.2.3.2 +5VDC Power FIPBSD-ON:CH1.2, CH1.1ProcedureTurn ON the power. Is the voltage between the LVPS J512-1 (+) and the GND (-) +5VDC?Y N- LVPS [120VAC] -Is the voltage between the LVPS J510-1 and J510-2 120VAC?- LVPS [220VAC] - Is the voltage between the LVPS J510-1 and J510-3 220 to240VAC?Y NGo to '2.2.3.1 AC Power FIP'.Turn OFF the power and disconnect the LVPS J512. After 15 s or longer has passed, turnON the machine. Is the voltage between the LVPS P512-1 (+) and the GND (-)+5VDC?Y NReplace the LVPS. (PL 18.1)Check the +5VDC circuit for a short circuit in the frame by referring to Chapter 7 WiringData.Check the wire to the applicable component for an open circuit or poor contact by referring toChapter 7 Wiring Data.