3 Wiring and Connection3.1.6 Precautions When Using the SERVOPACK with Single-phase, 200 V Power Input3-12(3) Parameter SettingWhen using a DC power supply, make sure to set the parameter Pn001.2 to "1" (DC power input supported)before inputting DC power.3.1.6 Precautions When Using the SERVOPACK with Single-phase, 200 V PowerInputSome models of Σ-V series three-phase 200 V power input SERVOPACK can be used also with a single-phase200 V power supply.The following models support single-phase 200 V power input.SGDV-R70A, -R90A, -1R6A, -2R8A, -5R5AWhen using the SERVOPACK with single-phase, 200 V power input, set parameter Pn00B.2 to 1.(1) Parameter Setting Single-phase Power Input Selection(2) Main Circuit Power InputConnect a single-phase 200 V power supply of the following specifications to L1 and L2 terminals.The specifications of the power supplies other than the main circuit power supply are the same as for three-phase power supply input.∗ Do not use L3 terminal.Parameter Meaning When Enabled ClassificationPn001 n.0 Enables use of AC power input. After restart Setupn.1 Enables use of DC power input.Parameter Meaning When Enabled ClassificationPn00Bn.0 Enables use of three-phase power supply for three-phaseSERVOPACK. [factory setting] After restart Setupn.1 Enables use of single-phase power supply for three-phaseSERVOPACK.WARNING• If a single-phase 200 V is input to a SGDV-R70A, -R90A, -1R6A, -2R8A, or -5R5A single-phase powerinput supported SERVOPACK without having changed the setting of Pn00B.2 to 1 (single-phase powerinput), the main circuit cable open phase alarm (A.F10) will be detected.• The SERVOPACK models, SGDV-R70A, -R90A, -1R6A, -2R8A, and -5R5A, support single-phase 200 Vpower input. If a single-phase 200 V is input to the SERVOPACK models that do not support single-phasepower input, the main circuit cable open phase alarm (A.F10) will be detected.• When using a single-phase 200 V power supply, the SGDV-R70A, -R90A, -1R6A, -2R8A, or -5R5A SER-VOPACK may not be able to produce the same servomotor force-speed characteristics as using a three-phase 200 V power input. Refer to the diagram of each motor force-speed characteristics inΣ-V SeriesProduct Catalog (KAEPS80000042).TerminalSymbols Name Model SGDV- RatingL1, L2, Main circuit powerinput terminals R70A, R90A,1R6A, 2R8A, 5R5ASingle-phase 200 V to 230 V,+10% to –15% (50/60 Hz)L3* – None