3.2 Ratings and Specifications of SGMPH (3000min -1 )3-133(5) Holding Brake Electrical SpecificationsNote: The holding brake is only used to hold the load and cannot be used to stop the servomotor.3.2.2 SGMPH Servomotors With Standard Backlash GearsHoldingBrake RatedVoltageServomotorModelServomotorCapacityWHolding Brake SpecificationsCapacityWHoldingTorqueN·m (oz·in)CoilResistanceΩ (at 20 °C)RatedCurrentA (at 20 °C)90 VDCSGMPH-01 100 8.1 0.318(45.0) 1000 0.09SGMPH-02 200 7.6 0.637(90.2) 1062 0.085SGMPH-04 400 7.2 1.27(180) 1125 0.08SGMPH-08 750 7.5 2.39(338) 1083 0.083SGMPH-15 1500 10 4.77(675) 832 0.10824 VDCSGMPH-01 100 8.1 0.318(45.0) 71 0.34SGMPH-02 200 7.6 0.637(90.2) 75.8 0.32SGMPH-04 400 7.6 1.27(180) 75.8 0.32SGMPH-08 750 7.5 2.39(338) 76.8 0.31SGMPH-15 1500 10 4.77(675) 57.6 0.42• Time Rating: Continuous • Thermal Class: B• Vibration Class: 15 μm or below • Withstand Voltage:100V, 200V Servomotors: 1500 VAC for one minute400V Servomotors: 1800 VAC for one minute• Insulation Resistance: 500 VDC, 10 MΩ min. • Enclosure: Totally enclosed, self-cooled, IP55 (exceptfor shaft opening)• Ambient Temperature: 0 to 40°C (32 to 104°F) • Ambient Humidity: 20% to 80% (no condensation)• Excitation: Permanent magnet • Drive Method: Direct drive• Mounting: Flange method • Backlash: 15 min max.• Gear Mechanism: Planetary gear mechanism • Gear Rotation Direction: Same direction as servomotor