YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07) 317A.3 Common Drive SpecificationsSpecificationsAA.3 Common Drive SpecificationsTable A.4 Common SpecificationsItem SpecificationRatingsHorsepower (kW) Range200 V Class(Single-Phase) 0.1 - 4.0 kW HP (HD)200 V Class(Three-Phase) 0.1 - 4.0 kW HP (HD)400 V Class(Three-Phase) 0.2 - 4.0 kW HP (HD)Performance FeaturesMax Output Frequency Hz 400 Hz standard, 1000 Hz optionalMax Output Voltage V All models(proportional to input voltage)Overload Rating % (ND) 120%, 1 minute(HD) 150%, 1 minutePWM Carrier FrequencyRange200 V Class (ND) 2 kHz Low Noise.(HD) 1-15 kHz (model dependent)400V ClassMotor Control MethodV/f YesOpen Loop Vector Yes (current vector)Open Loop Vector for PM(for use with PM motors) YesSpeed Regulation/Accuracy V/f +/-1%Open Loop Vector +/-0.2%Speed RangeV/f 40:1Open Loop Vector 100:1Open Loop Vector Control forPM motors 10:1Frequency Setting ResolutionDigital Reference Digital Command: 0.1 Hz (under 100 Hz)1 Hz (100 Hz and higher)Analog Reference Analog Command: Max Frequency1/1000 (10 bit)Output Frequency Resolution 0.001 HzFrequency ReferenceAccuracyDigital Reference Digital Command: ±0.01% of max. outputfrequency (-10~+50º C)Analog Reference Analog Command: ±0.5% of maximumoutput frequency (25º C±10º C)Frequency Control Range ~ 0.01 to 400.0 HzSpeed Response Open Loop Vector 5 Hz at 20º C±10º CStarting Torque at Low Speed V/f 150% at 3 Hz