Manual VIPA System 200V Chapter 4 Serial communicationHB97E - CPU - RE_21x-2BS03 - Rev. 15/16 4-13Interface parametersThe parameter transfer to the communication processor happens duringruntime by using the SFC 230 with order no. 201. The parameters for theprotocols have to be stored in a DB.To activate the parameters you have to execute a RESET with SFC 234after transfer.General parameters for every channel in use:Data byte Type Designator Values Default0 BYTE Channel COM 1COM 2121 BYTE Mode MODI_NONE (deactivated)MODI_1 (Parameter following)081h02 BYTE Baudrate BAUDRATE_DEFBAUDRATE_150BAUDRATE_300BAUDRATE_600BAUDRATE_1K2BAUDRATE_1K8BAUDRATE_2K4BAUDRATE_4K8BAUDRATE_7K2BAUDRATE_9K6BAUDRATE_14K4BAUDRATE_19K2BAUDRATE_38K4BAUDRATE_57K600h01h02h03h04h05h06h07h08h09h0Ah0Bh0Ch0Dh09h3 BYTE DataBits DATABIT_5DATABIT_6DATABIT_7DATABIT_8012334 BYTE Parity PARITY_NONEPARITY_ODDPARITY_EVEN01305 BYTE StopBits STOPBIT_1STOPBIT_1_5STOPBIT_212316 BYTE FlowControl FLOW_NONEFLOW_HARDWAREFLOW_XON_XOFF01217 BYTE Protocol PROTOCOL_ASCIIPROTOCOL_STXETX_HTBPROTOCOL_3964PROTOCOL_3964RPROTOCOL_3964_RK512PROTOCOL_3964R_RK51201h02h03h04h05h06h01hParameter-DBstructure