1 Spot Welding Application Using a Motor Gun1.3 Setting of Motor Gun1-211.3.9 Setting of Torque to Pressure Conversion DataAfter the execution of Motor Gun Auto Turning function, by following theprocedure below, re-measure the pressure and reset the torque topressure conversion data.1. Set a value to {THICKNESS FORCE GAUGE} and select “ENABLE” at{PRESS MEASUREMENT MODE} on MANUAL PRESS window.2. Set the pressure value to the pressure file.– As the unit of this pressure, specify torque(%).– Specify 5(%) to the touch speed of the pressure file.3. Register SVGUNCL instruction to a JOB.– Specify the pressure file set at the step 2.4. Execute the JOB and measure the pressure with the force gauge.5. Execute the above procedures 2 through 4 with the different torque(%)to measure a torque(%) for the pressure.6. Input the acquired data to “Torque to pressure conversion” in the guncondition file. Up to 12 data can be registered.NOTEOn MANUAL PRESS window, set a value to {THICKNESSFORCE GAUGE} and select “ENABLE” to {PRESS MEA-SUREMENT MODE}.The PRESS MEASUREMENT MODE becomes “UNABLE”in case the mode is changed from the teach mode to theplay mode. Set “ENABLE” again when the mode ischanged.31 of 198