Contents - Table Of Contents
- Table Of Contents
- Installation manual
- safety instructions
- Instructions for storage, transport, loading and unloading of the unit
- technical data
- ARH technical and physical data (heat pump) and ARD (heat pump + gas heat)
- Weight options and accessories
- Limits of use
- Hot water coil, optional in ARC/ARH
- Measurements, clearances and accesses
- General dimensions and accesses (models 045/060)
- General dimensions and accesses (models 075/090)
- return air
- ARC/ARG 075 Cooling capacities
- ARH/ARD Output
- ARH/ARD 075 Cooling capacities
- ARH/ARD 060 Thermodynamic heat capacity
- indoor fan
- Output table for indoor fan, model ARC-045, applications with side ducts, standard drive motor 3 kW
- motor 5.5 kW
- Output table for indoor fan, model ARC/ARH-090, applications with side ducts, standard drive motor 7.5 kW and optional HPD motor 9.2 kW
- Instructions for installation and connection of the unit
- Specifications for the foundation or anchoring of the unit
- electrical checks
- Starting the gas heating, ARG/ARD
- Unblocking the unit safely in case of breakdown
- Regular maintenance tasks performed by specialised personnel
- Maintenance tasks performed by specialised personnel
- air filters
- outdoor coils
- Gas heating (ARG/ARD Models)
- Unit sound pressure data
- Unit installation data
- List of tests for unit start-up
- Start-up Data
|
* Data in accordance with Eurovent Rooftop program certification conditionsPT: Total Power; PC: Power absorbed by the compressorWB: Wet-bulb temperature; TS: Dry bulb temperature.1.12 ARH/ARD Output1.12.1 ARH/ARD 045 Cooling capacitiesReturn air Outdoor coil air temperature (TS)Flowm3/hTHºC27 ºC 35 ºC 46 ºCPTkWPCkWSensible power kWPTkWPCkWSensible power kWPTkWPCkWSensible power kWInput temp. TS in indoor coil Input temp. TS in indoor coil Input temp. TS in indoor coil30 27 24 22 30 27 24 22 30 27 24 22(Mini‐mum)700023 53.7 11.1 31.8 25.2 18.6 - 50.9 12.2 30.8 41.3 17.6 - 45.9 13.5 29.2 22.6 16 -19 48.6 10.8 41.7 35.1 28.5 24.1 45.9 11.7 40.6 24.2 27.4 23 41.3 12.6 39 32.3 25.7 21.317 45.9 10.5 45.9 40 33.3 32.5 42.2 11.6 42.2 34 31.6 29.2 37.6 12.5 37.6 36.3 29.8 25.415 41.3 10.4 41.3 41.3 36.9 32.5 39.5 11.3 39.5 38.2 36 31.6 35.3 12.4 35.3 35.3 34.2 29.8(Nominal)850023 55.7 11.3 34.9 27.1 19.2 - 52.8 12.4 33.9 26.1 18.3 - 47.6 13.7 32.3 24.5 16.6 -19 50.5 10.9 46.6 38.8 30.9 25.7 47.6* 11.9* 45.5 37.6* 29.8 24.6 42.8 12.9 42.8 35.9 28.1 22.917 47.6 10.7 47.6 44.5 36.6 36.8 43.8 11.8 43.8 42.7 34.9 32.4 39 12.7 39 39 33 27.815 42.8 10.6 42.8 42.8 41.1 35.9 40.9 11.5 40.9 40.9 40.1 34.9 36.7 12.6 36.7 36.7 36.7 33.1(Maxi‐mum)1000023 57.25 11.5 37.9 28.9 19.8 - 54.3 12.6 37 27.9 18.8 - 48.9 213.9 35.3 26.3 17.2 -19 51.8 11.1 51.3 42.2 33.2 27.2 48.9 12.1 48.9 41.1 32.1 26 44 13.1 44 39.4 30.3 24.317 48.9 10.9 48.9 48.8 39.7 41.3 45 12 45 45 37.9 35.6 40.1 12.9 40.1 40.1 36.1 3015 44 10.8 44 44 44 39 42.1 11.7 42.1 42.1 42.1 38 37.6 12.8 37.6 37.6 37.6 36.2* Data in accordance with Eurovent Rooftop program certification conditionsPT: Total Power; PC: Power absorbed by the compressorWB: Wet-bulb temperature; TS: Dry bulb temperature.1.12.2 ARH/ARD 060 Cooling capacitiesReturn air Outdoor coil air temperature (TS)Flowm3/hTHºC27 ºC 35 ºC 46 ºCPTkWPCkWSensible power kWPTkWPCkWSensible power kWPTkWPCkWSensible power kWInput temp. TS in indoor coil Input temp. TS in indoor coil Input temp. TS in indoor coil30 27 24 22 30 27 24 22 30 27 24 22(Mini‐mum)950023 69.8 14.2 42.2 33.1 24.1 - 66.3 15.5 40.9 31.9 22.8 - 59.7 17.1 38.8 29.8 20.7 -19 63.2 13.7 55.7 46.7 37.7 31.6 59.7 14.9 54.3 45.2 36.3 30.2 53.7 16.1 52.1 43 34 2817 59.7 13.4 59.7 53.3 44.3 42.5 54.9 14.8 54.9 51 42 38.3 48.9 15.9 49 48.7 36.7 33.615 53.7 13.3 53.7 53.7 49.3 43.3 51.3 14.5 51.3 51.3 48 42 46 15.8 46 46 45.8 39.8(Nomi‐nal)1150023 72.4 14.4 46.5 35.8 25 - 68.7 15.8 45.2 34.5 23.8 - 61.9 17.5 43.2 32.4 21.7 -19 65.6 14 62.4 51.7 41 33.8 61.9* 15.2* 61 50.3* 39.5 32.4 55.7 16.4 55.7 48 37.3 30.117 61.9 13.7 61.9 59.5 48.7 48.1 56.9 15 56.9 56.9 46.5 42.5 50.8 16.3 50.8 50.8 44.1 36.915 55.7 13.5 55.7 55.7 55 47.8 53.2 14.7 53.2 53.2 53.2 46.5 47.7 16.1 47.7 47.7 47.7 44.2(Maxi‐mum)1350023 74.4 14.6 50.7 38.2 25.8 - 70.6 16 49.4 37 24.6 - 63.6 17.7 47.3 34.9 22.5 -19 67.4 14.2 67.4 56.5 44.1 35.8 63.6 15.4 63.6 55.1 42.6 34.3 57.2 16.6 57.2 52.8 40.2 32.117 63.6 13.9 63.6 63.6 53 53 58.5 15.2 58.5 58.5 50.8 46.6 52.1 16.5 52.1 52.1 48.3 4015 57.2 13.7 57.2 57.2 57.2 52.1 54.7 14.9 54.7 54.7 54.7 50.8 49 16.3 49 49 49 48.6* Data in accordance with Eurovent Rooftop program certification conditionsPT: Total Power; PC: Power absorbed by the compressorWB: Wet-bulb temperature; TS: Dry bulb temperature.Installation manual 1ARH/ARD Output 1.1215
PreviousNext |