Contents - Table Of Contents
- Table Of Contents
- Installation manual
- safety instructions
- Instructions for storage, transport, loading and unloading of the unit
- technical data
- ARH technical and physical data (heat pump) and ARD (heat pump + gas heat)
- Weight options and accessories
- Limits of use
- Hot water coil, optional in ARC/ARH
- Measurements, clearances and accesses
- General dimensions and accesses (models 045/060)
- General dimensions and accesses (models 075/090)
- return air
- ARC/ARG 075 Cooling capacities
- ARH/ARD Output
- ARH/ARD 075 Cooling capacities
- ARH/ARD 060 Thermodynamic heat capacity
- indoor fan
- Output table for indoor fan, model ARC-045, applications with side ducts, standard drive motor 3 kW
- motor 5.5 kW
- Output table for indoor fan, model ARC/ARH-090, applications with side ducts, standard drive motor 7.5 kW and optional HPD motor 9.2 kW
- Instructions for installation and connection of the unit
- Specifications for the foundation or anchoring of the unit
- electrical checks
- Starting the gas heating, ARG/ARD
- Unblocking the unit safely in case of breakdown
- Regular maintenance tasks performed by specialised personnel
- Maintenance tasks performed by specialised personnel
- air filters
- outdoor coils
- Gas heating (ARG/ARD Models)
- Unit sound pressure data
- Unit installation data
- List of tests for unit start-up
- Start-up Data
|
Flowm3/hReturnair TSºCOutdoor air temperature TS ºC-10 -5 0 5 7 10 15 20PT PC PT PC PT PC PT PC PT PC PT PC PT PC PT PC25 47 18.2 53.1 19 60.1 19.8 67.8 20.3 71 21.2 76.2 22 85.4 23.5 95.2 24.4* Data in accordance with Eurovent Rooftop program certification conditionsPT: Total Power; PC: Power absorbed by the compressorWB: Wet-bulb temperature; TS: Dry bulb temperature.1.12.8 ARH/ARD 090 Thermodynamic heat capacityFlowm3/hReturnair TSºCOutdoor air temperature TS ºC-10 -5 0 5 7 10 15 20PT PC PT PC PT PC PT PC PT PC PT PC PT PC PT PC(Minimum)1300014 57.7 18.4 65.2 19.2 73.9 20 83.3 20.5 87.3 21.4 93.6 22.2 105 23.8 117 24.617 57.1 20 64.5 20.8 73 21.7 82.3 22.2 86.3 23.2 92.5 24 103.7 25.8 115.7 2720 56.4 20.4 63.7 21.2 72.1 22.2 81.4 22.7 85.3 23.7 91.4 24.6 102.5 26.3 114.3 27.323 55.6 21.8 62.9 22.7 71.2 23.7 80.3 24.3 84.2 25.4 90.2 26.3 101.2 28.2 112.8 29.225 55.3 22.5 62.5 23.4 70.8 24.4 79.8 24.9 83.7 26.1 89.7 27 100.6 29 112.1 30(Nominal)1600014 58.5 17.9 66.2 18.6 74.9 19.4 84.5 19.8 88.6 20.8 95 21.5 106.5 23 118.7 23.917 57.9 19.3 65.4 20.1 74 21 83.5 21.5 87.5 22.5 93.8 23.3 105.2 25 117.3 25.920 57.2 19.8 64.6 20.6 73.2 21.5 82.5 22 86.5* 23* 92.7 23.8 104 25.5 116 26.423 56.4 21.2 63.8 22 72.2 23 81.4 23.5 85.4 24.6 91.5 25.5 102.6 27.3 114.4 28.325 56.1 21.8 63.4 22.6 71.8 23.7 81 24.2 84.9 25.3 91 26.2 102 28.1 113.7 29.1(Maximum)1800014 59.1 17.4 66.8 18.1 75.7 18.9 85.3 19.3 89.5 20.2 96 20.9 107.5 22.4 119.9 23.317 58.4 18.8 66 19.6 74.8 20.5 88.4 20.9 88.4 21.9 94.8 22.7 106.3 24.3 118.5 25.220 57.7 19.3 65.3 20 73.9 20.9 83.3 21.4 87.4 22.4 93.7 23.2 105 24.8 117 25.823 57 20.6 64.4 21.4 73 22.4 82.3 22.9 86.2 24 92.4 24.8 103.6 26.6 115.5 27.625 56.7 21.2 64 22 72.5 23 81.8 23.5 85.7 24.6 91.9 25.5 103 27.3 114.8 28.3* Data in accordance with Eurovent Rooftop program certification conditionsPT: Total Power; PC: Power absorbed by the compressorWB: Wet-bulb temperature; TS: Dry bulb temperature.1.13 Indoor fan1.13.1 Features tableModel Fan kitMotor (1) Motor pulley (adjustable) Fan pulley (fixed) BeltkW Type of cas‐ing ∅ pulley (mm) ∅ shaft(mm)∅ pulley(mm)∅ shaft(mm) Length (mm) Ref. Qty.045 Standard 3 100 LB 109-135 28 236 25 1840 BX71 1Option HPD 4 kW 4 100 LC 109-135 28 190 25 1740 BX67 1060 Standard 4 100 LC 124-150 28 236 25 2040 BX79 1Option HPD 5.5 kW 5,5 112 MB 147-178 28 236 25 2040 BX79 1075 Standard 5,5 112 MB 124-150 28 236 25 2040 BX79 1Option HPD 7.5 kW 7,5 132 M 147-178 38 236 25 2123 BX82 1090Standard 7,5 132 M 139-173 38 250 35 2040 BX79 2Option HPD 9.2 kW 9,2 132 MBA 139-173 38 250 35 2040 BX79 2Option HPD 11 kW 11 132 MB 152-190 38 250 35 2040 BX79 2(1) All motors are totally closed, cooled by fans at 1450 r/min, with a solid base and a service factor of 1.15.Inside fan output tables for determining the motor pulley adjustment and the type of drive needed for the installation.1.13.2 Considerations when consulting the output tablesIndoor fan output tablesFor units with 0% outdoor air and 100% return air, dry indoor coil, and standard G4 filters.1 Installation manual1.13 Indoor fan18