DMS 80 / DMS 160 / DMS 240 / DMS 240 HSRwww.dallmeier.com 49TimerThe recording is started by the contact switching. Recording is stopped After the ContactRecording Duration expired.ToggleThe recording is triggered by the contact switching. It is stopped again by the same contactswitching again.MarkA marker (index) will be saved to the track when the contact is triggered. While playing backtheses markings can be searched (index search and extended search).6.4.1.4 Switching by motionIn the recording mode Switching by motion recording initially is done with normal videoquality. Thereby every image send by the camera will be analyzed. If a change of a certainproportion of the picture content is detected between two consecutive images, an imagecomparison event (event) has taken place. This picture comparison event triggers the swit-ching to permanent recording with high video quality.Recording with high video quality will be stopped when the Switching Duration is expi-red and no further motion is detected.¾ Ensure that the Expert Mode option is activated.¾ Set the Switching by motion recording mode.¾ Observe the explanations given below.Fig. 6-23 : Switching by motion recording mode¾ Configure Private Zones if required (see section Basic configuration).¾ Activate / configure the Camera Timer if required (see section Basic configuration).¾ Activate the Use Database option if required (see above).¾ Configure the Active Areas if required (see section Basic configuration).¾ Set the Sensitivity of the motion detection (see above).¾ Set the Switching Duration.¾ Set the Motion Estimation for the memory calculation (see above).¾ Confirm with OK.