We reserve the right to make changes21Domestic hot waterUserSuperuserInstallerTemperature - Domestic hot waterYou can set the desired domestic hot water temperature.The temperature of the hot water is set in the temperature:• CP/Hot water (°C) You can set the desired domestic hot water temperature.Adjustable between 10 and 65°C(factory setting: 45°C).Temperature - Electrical supplementary Domestic hot waterThe electrical supplementary of 1.5 kW ensures hot water during periods when the heat pump cannot deliverenough energy.Electrical supplementary is set in the Settings menu:• CP/SHW settings/SHW heater enable Switch electrical supplementary domestic hot water ON or OFFOn: electrical supplementary is enabledOff: electrical supplementary is disabled(factory setting: OFF)Temperature - Min./max temperature Domestic hot waterMin./max temperature for the Domestic hot water is set in the Settings menu:• CP/SHW settings/SHW minimum temp. (°C) If the temperature in the hot water tank falls below this temperature,electrical supplementary will start(factory setting: 36°C).CP/Hot water/SHW max. temp. (°C) This temperature setting ensures that the compressor is not athigh pressure when no more hot water is needed.(factory setting: 60°C)Read Min. /Max temperature of the hot water in the Temperature menu:• CP/T11 (°C) The temperature sensor in the hot water tank top.• CP/T12 (°C) The temperature sensor in the hot water tank base.