We reserve the right to make changes22Domestic hot waterUserSuperuserPause - Domestic hot waterIt is possible to temporarily shut down hot water production. This may be a good idea when you go on holiday.The production of hot water is paused in the Standby menu:• CP/Pause SHW Hot water production shut down until the next change in the weekly schedule.If you wish to pause hot water production while you are on holiday, any weekly schedule that you have created mustbe deactivated.Legionella combat system - Start Legionella combat system now.The legionella combat system can be set to function automatically, but it is also possible to start it at any time thatsuits you.The legionella combat system is started in the Settings menu:• CP/Legion mode/Start legionella now You can start the legionella combat system manually.If you have been away on holiday for a long time and during this period have stopped the hot water production, it maybe beneficial to start the legionella function manually.Legionella combat system - SettingsThe legionella combat system can be set to function automatically.The legionella combat system is set in the Settings menu:• CP/Legion mode You can activate the combat system.Off: Legionella combat system inactive.Weekly: Legionella combat system runs once a week.Monthly: Legionella combat system runs once a month(factory setting: Off).• CP/Legion mode/Day for anti-legionella Weekday or month in which the legionella combat system will run.• CP/Legion mode/Legionella start (h) Time of day at which the legionella combat system will start.The legionella combat system runs by heating the hot water to 65°C for 5 minutes. It is therefore a good idea to do thisa good time before showering, to avoid scalding.