We reserve the right to make changes24General SettingsSuperuserDevices data - Compact P (Fan and domestic hot water).It is possible to read off the system's current status.Read data can be found in the Information menu:• CP/Devices You can read system Compact P mode here (ventilation and hot water).- Supply fan (%) This displays the supply air fan's current operating status.- Extract fan (%) This displays the extract air fan's current operating status.- Bypass damper Specifies whether the bypass damper is open or closed.- Supply filter guard(%) Soiling- Extract filter guard (%) Soiling- Reheater (%) The running capacity of the heating coil.- Compressor level Specifies whether the compressor is ON (on) or OFF (off).- Four-way valve Indicates whether the 4-way valve is open (on) or closed (off).- Ice-protecting heating element (%) The running capacity of the preheating element (only Polar model).- Humidity (% RH) States the average humidity measured over the last 24 hours.- CO2 (ppm) Indicates the current CO2 level.- Fire alarm Indicates whether the fire thermostat is activated.- User select 1 in Indicates whether the user selection 1 is activated (on) or deactivated (off).- User select 2 in Indicates whether the user selection 2 is activated (on) or deactivated (off).- Allow external cooling States whether cooling via external system is released or not.- Allow external heat States whether heat via external system is released or not.- User select 2 out Indicates whether the user selection 2 is active.- Legionella Indicates whether the legionella combat system is active (on) or inactive (off).- HP Alarm States whether there is a high pressure alarm in the heat pump system.- SHW sacrificial anode In the event of an error, it may have to be replaced.- SHW electric heater Indicates whether the electric heater is active (on) or not active (off).- De-icing Indicates whether the de-icing is active (on) or not active (off).- Alarm States whether there are active alarms.- Heating or cooling is blocked No blockage (Off); heating or cooling is blocked (On).- Brine pressostat For a BAH solution, indicates whether the brine circuit is OK.- Heat valve open Indicates whether the heat pump is heating the air intake (Open) or not (Close).- Hot water valve open Indicates whether the heat pump is producing hot water (Open) or not (Close).NB! ”Heating valve open” and ”hot water valve open” may be shut off at the same time, but they may not both be openat the same time.NB! If the 4-way valve is open and de-icing is not activated, the system’s cooling function must be operating.