Enclosure Object and Element Commandswww.3ware.com 116/cx/ex show fansThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command lists the fans in enclosure /cx/ex and shows their status.Example://localhost> /c0/e0 show fans---Speed---Fan Status State Step RPM Identify------------------------------------------------------------fan0 OK ON 1 2670 Offfan1 OK ON 1 9370 Offfan2 OK ON 1 8540 Offfan3 OK ON 1 2810 Offfan4 OK ON 1 9240 Offfan5 OK ON 1 8330 Off/cx/ex show tempThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command lists the temperature sensors in enclosure /cx/ex and thecurrent temperature.The maximum temperature for successful use of a drive should be noted in thedocumentation for the drive.Example://localhost> /c0/e0 show tempTempSensor Status Temperature Identify--------------------------------------------------------temp0 OK 41C(105F) Offtemp1 OK 37C(98F) Offtemp2 OK 34C(93F) Offtemp3 OK 38C(100F) Offtemp4 OK 38C(100F) Offtemp5 OK 34C(93F) Offtemp6 NOT-INSTALLED - Offtemp7 NOT-INSTALLED - Off