Enclosure Object and Element Commandswww.3ware.com 118/cx/ex/slotx show identifyThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command shows the identify status of the specified slot. The status canbe either on or off.Example://localhost> c0/e0/slot1 show identify/c0/e0/slot1 Identify status = on/cx/ex/slotx set identify=on|offThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command causes the slot to be identified by blinking the LED associatedwith it, or turns off identification of the LED for this slot.Setting identify to on will cause the LED associated with that slot to blink.Note: This command is equivalent to “/cx/px set identify=on|off” onpage 105.Example://localhost> c0/e0/slot1 set identify=onSetting Slot Identify c0/e0/slot0 to [on] ... Done./cx/ex/fanx showThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command shows the information about the specified fan element /fanx inthe specified enclosure cx/ex. The fan name is followed by its status. If a fanis on and no fault has been detected, the status would indicate OK.Example://localhost> /c0/e0/fan0 show---Speed---Fan Status State Step RPM Identify------------------------------------------------------------fan0 OK ON 1 2700 Off