Chapter 2. CLI Syntax Reference119 3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.1/cx/ex/fanx show identifyThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command shows the identify status of the specified fan. The status can beeither on or off.Example://localhost> c0/e0/fan1 show identifyc0/e0/fan1 Identify status = on/cx/ex/fanx set identify=on|offThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command causes the fan to be identified by blinking the LED associatedwith it, or turns off identification of the LED for this fan.Setting identify to on will cause the LED associated with that fan to blink.Example://localhost> c0/e0/fan1 set identify=onSetting Fan Identify on c0/e0/fan1 to [on] ... Done./cx/ex/pwrsx showThis command is used with the 9690SA controller. For the 9650SE and CCUenclosure, simply drop the prepended controller name in the command anduse /ex.This command shows the information about the specified power supplyelement /pwrsx in the specified enclosure cx/ex. The power supply name isfollowed by its status. The possible status values are OK, FAIL, NOT-INSTALLED, and OFF. The possible values for voltage are OK, OVER-VOLTAGE, and UNDER-VOLTAGE. The possible values for current areOK, OVER-CURRENT. In either case, OVER- means over the set thresholdof the voltage or current.If a power supply is on and no fault has been detected, the status wouldindicate OK.