Chapter 8. Configuring Units116 3ware Serial ATA RAID Controller User GuideThe page refreshes, and a message at the top confirms the change youhave made.To set the Continue on Source Error During Rebuild policy in 3BM1 At the main 3BM screen, select the unit by highlighting it and pressingEnter.An asterisk appears in the left-most column to indicate that it is selected.2 Tab to the Maintain Unit button and press Enter.3 On the pop-up menu, select Configure and press Enter.4 In the Configure Disk Array screen, Tab to the field Continue onSource Error During Rebuild.5 Press Enter to display the choices, use the arrow keys to select thesetting you want (Enabled or Disabled), and press Enter again to chooseit.6 Tab to the OK button and press Enter to select it.You return to the main 3BM screen.7 When you are finished making changes, press F8 to save them and exit3BM.Enabling and Disabling Queuing for a UnitSome drives support NCQ (Native Command Queuing), a feature that canresult in increased performance for applications that require a lot of randomaccess of data (usually server-type applications). This is accomplished bycausing command reordering to be done on the drive.In order to make use of NCQ, the feature must be enabled at both the driveand the controller. You can enable support for NCQ on a per-unit basis, asdescribed below.You can see whether NCQ is supported and enabled for a particular drive inthe Drive Details window. For details, see “Drive Details window” onpage 196.Note: Not all drives support NCQ. If a drive does not support NCQ, the policysetting for the controller is ignored.