Connecting a remote panel, or chaining one panel to severaldrivesYou can connect a remote ACH-AP-H control panel to the drive, or to chain the control panelor a PC to several drives on a panel bus with a CDPI-01 communication adapter module.See CDPI-01 communication adapter module user's manual (3AXD50000009929 [English]).Connecting a PCA PC (with eg, the Drive composer PC tool) can be connected as follows:1. Connect an ACx-AP-x control panel to the unit either• by inserting the control panel into the panel holder or platform, or• by using an Ethernet (eg, Cat 5e) networking cable.2. Remove the USB connector cover on the front of the control panel.3. Connect an USB cable (Type A to Type Mini-B) between the USB connector on thecontrol panel (3a) and a free USB port on the PC (3b).4. The panel will display an indication whenever the connection is active.5. See the documentation of the PC tool for setup instructions.?StartStop Loc/Rem?StartStop Loc/RemUSB connected3a43b2272 Electrical installation