- Contents of this chapter
- General safety in installation, start-up and maintenance
- Electrical safety in installation, start-up and maintenance
- Optical components
- Additional instructions for permanent magnet motor drives
- Quick installation and commissioning flowchart
- Terms and abbreviations
- Related documents
- Layout
- Frame size R3
- Frame R4...R8
- External control connecting terminal, Frame size R0...R2
- External control connecting terminal, Frame size R3...R5
- External control connection terminals, frames R6...R8
- Control panel
- Type designation label
- Locations of the labels on the drive
- Type designation key
- Checking the installation site
- Required tools
- Unpacking and examining delivery, frames R0...R2
- Unpacking and examining delivery, frames R5
- Unpacking and examining delivery, frames R6...R8
- Installing the drive
- Installing the drive vertically, frame size R3...R4
- Installing the drive vertically, frames size R5...R8
- Installing the drive vertically side by side
- Other regions
- Alternative power cable types
- Recommended power cable types
- Conduit
- Signals in separate cables
- Routing the cables
- General guidelines, North America
- Continuous motor cable shield or enclosure for equipment on the motor cable
- Protecting the motor against thermal overload
- Using a contactor between the drive and the motor
- Switching the motor power supply from drive to direct-on-line
- Switching the motor power supply from direct-on-line to drive
- Input power cable
- Ground-to-phase varistor
- Frames R4...R8
- Connecting the power cables
- Connection procedure: frames R0...R2
- Finalization
- Connection procedure, frames R3...R4
- Note
- Connection procedure, frames R5...R8
- DC connection
- Default control connections of ABB standard macro
- Notes
- NPN configuration for digital inputs
- Connection examples of two-wire and three-wire sensors
- DI5 as frequency input
- Control cable connection procedure R0...R8
- R0...R2
- R3...R5
- R6...R8
- Front option slot 1
- To remove a front option
- Reinstalling side plates and covers, frames size R5...R8
- Recommended annual maintenance actions by the user
- Heatsink
- Replacing the cooling fan, frames size R0...R4
- Replacing the main cooling fan, frames size R6...R8
- Replacing the auxiliary cooling fan, frames R6...R8
- Capacitors
- LEDs
- Definitions
- Derating
- Switching frequency derating
- Altitude derating
- gG fuses
- gR fuses
- DC fuses
- Circuit breakers
- Dimensions, weights and free space requirements
- Thermal losses, cooling data and noise
- Terminal and lead-through data for the power cables
- Terminal and lead-through data for the control cables
- Electrical power network specification
- EMC compatibility and motor cable length
- Control connection data
- Auxiliary circuit power consumption
- Efficiency
- For R3...R8
- Materials
- CE marking
- Category C1
- Category C4
- Frame R0, IP20
- Frame R1, IP20
- Frame R3, IP20
- Frame R4, IP20
- Frame R5, IP20
- Frame R6, IP20
- Frame R7, IP20
- Frame R8, IP20
- Compliance with the European Machinery Directive
- Wiring
- Wiring examples (R0...R2)
- Connection principle (R3...R8)
- Wiring examples (R3...R8)
- Cable types and lengths
- Operation principle
- Start-up including acceptance test
- Maintenance
- Fault tracing
- Safety data
- Abbreviations
- Electrical installation
- Start-up
- Dimensions
|
gG (IEC 60269)Input cur-rentMinimumshort cir-cuit cur-rent 1)Drive typeACQ80-04-IEC 60269sizeABB designa-tion typeRatedvoltageI2tRated cur-rent INVA2sAAA000OFAF000H2550025002520.220005kW5-4000OFAF000H3250045003227.225607kW5-4000OFAF000H50500155004040.03011kW-4000OFAF000H4050077004033.0320015kW-4000OFAF000H50500160005039.040018kW5-4000OFAF000H63500201006345.0500022kW-4000OFAF000H80500375008062.0800030kW-4000OFAF000H1005006500010073.01000037kW-4000OFAF000H1005006500010088.01000045kW-400OFAF000H125500103000125106.01300055kW-400OFAF000H160500185000160145.01700075kW-40OFAF000H250500600000250169.03300090kW-41OFAF000H315500710000315206.05500110kW-41OFAF000H355500920000355246.06400132kW-42OFAF000H4255001300000425293.07800160kW-41) minimum short-circuit current of the device3AXD10000715646.xls■ gR fusesgG (IEC 60269)Input cur-rentMinimumshort cir-cuit cur-rent 1)Drive typeACQ80-04-IEC 60269sizeABB desig-nation typeRatedvoltageI2tRated cur-rent INVA2sAAA3-phase UN = 380…480 V00170M2694690125254.2480kW75-400170M2694690125255.34801kW1-400170M2695690275326.48001kW5-400170M2695690275329.08002kW2-400170M26966904904011.512803kW0-400170M26966904904015.012804kW0-400170M269769010005020.220005kW5-400170M269869018006327.225607kW5-4Technical data 117