Installation69InstallationWhat this chapter containsIn this chapter, the drive module is installed in a 400 mm wide Rittal TS 8 cabinet in abookshelf way of mounting: The module is placed in an upright position on thecabinet bottom with its front facing the cabinet door. The following Rittal parts anddrive module options are used in the installation examples:Always follow the general rules given in this chapter and local laws and regulations.ABB does not assume any liability whatsoever for any installation which breacheslocal laws and/or other regulations.Note 1: The drive module can also be installed in other than Rittal TS 8 cabinets.Drive module standard parts• Drive module• Top guide plate• Fastening bracket• Grounding busbar• Pedestal guide plate• Telescopic extraction and insertion ramp• Fastening screws in a plastic bag• External control unitDrive module optionsOption code Qty(pcs)Description+H381 1 Power cabling panels and a rubber grommet+H383 Power cabling panels+P905 1 Internal control unitRittal partsRittal part code Qty(pcs)DescriptionTS 8406.510 1 Enclosure without mounting plate. Includes frame, door, side and backpanels.TS 8612.160 5 Punched section with mounting flange, outer mounting level for 600 mmhorizontalTS 8612.140 3 Punched section with mounting flange, outer mounting level for 400 mmhorizontalSK 3243.200 2 Air filter 323 mm × 323 mmTS 4396.500 3 Support rails (alternative to a customer-made bottom plate)Customer-made parts (not ABB or Rittal products)Air baffles 6 See section Frames G1 and G2 – Air baffles on page 151 for thedimension drawings of the air baffles required in the cabinet.Cabinet bottomplate (alternative toRittal support rails)1 See Frames G1 and G2 – Bottom plate on page 150 for the dimensiondrawing of a customer-made bottom plate.