BUS C H- /AB B- S ECU R E @ HO M E2CSM 6 0072 7D0 9 01 2 5 /56- Away mode, i.e. the intrusion alarm with the anti-intrusion system armed in awaymode. This section also includes the Panic and system tampering (when system isarmed) and zone (always) alarm.- Home mode, i.e. the intrusion alarm with the anti-intrusion system armed in homemode.- Notification mode, i.e. the intrusion alarm with the anti-intrusion system armed innotification mode.- Technological, i.e. any of the technological alarms configured (flooding, gas leak,etc.), including when the anti-intrusion alarm system is deactivated.A new screen appears:A value can be selected using the arrow keys. The following parameters can be configured:- Sound type; beep or continuous sound- Sound duration, i.e. for how long the central unit buzzer should sound. (0-30sec-1-2-3-4-5-6-7-8-9min).- Default: 3 min for Away mode and Home model intrusion alarms, 30 seconds for Pre-alarm and technological alarm.Zones filter: allows you to select the zones to be taken into account in the event of an alarm(only for intrusion alarms and sensor tempering alarms). Factory settings include all zones. Ifthe alarm occurs in an excluded zone, the internal siren will not be triggered.8.3 Setting date and timeSetting the date and time is fundamental for correct storage of events in the log according totimes.The central unit automatically handles the summer time/winter time switchover and viceversa.To set the date and time:1. Log in as a level 2 user2. Use the arrow keys to select the Options icon and press ok.Type of soundSound Duration:< 3 min >Options