Chapter 6. Upgrading Software61203153L2-20 Express 3000 User Manual 6-3UPGRADING SOFTWARE USINGHYPERTERMINALInstructions for Upgrading Software Using HyperTerminalStep Action1 Download the necessary upgrade files from theADTRAN web site (www.adtran.com).2 Connect to the Express 3000 via HyperTerminal:a. Windows 95Start > Programs> Accessories > HyperTerminalWindows 98Start > Programs> Accessories > Communication> HyperTerminalb. When the Connection Description window opens,type in a connection name, select an icon, and clickOK.c. In the Connect To window, go to the Connect usingfield and select the COM port to which theExpress 3000 is connected; click OK.d. The COM port Properties window opens next.Change the Bits per second field to 57600 and clickOK.3 Type AT!FLASHLOAD to initiate the firmware update.The AT command is not visible since echo is off by de-fault. (To enable echo, type ATE1.)4 Click the Transfer menu; then click Send File….5 Click Browse to locate the directory and file to downloadto the Express 3000.