Section 3 Engineering Guidelines TRACER 6000 Series Integrated System Manual32 Copyright © 2005 ADTRAN, Inc. 612806420L1-1FAUX RS232 Interface (RJ-45)The AUX RS232 interface provides a female RJ-45 terminal connection (wired as a DCE interface), usedfor a 9600 bps point-to-point connection between the local and remote systems (over the RF link). Table 3shows the pinout.STATUSMOD1 and MOD2 Green the module is installed and functioning properly.Red (solid) a port on the installed module is currently in alarm.Off no module occupies the slot.PLAN AGreen (solid) the TRACER is transmitting on Frequency Plan A.Off the TRACER is not transmitting on Frequency Plan A.PLAN BGreen (solid) the TRACER is transmitting on Frequency Plan B.Off the TRACER is not transmitting on Frequency Plan B.RF LO Red (solid) the RSSI level is below suggested minimum threshold(approximately 10 dBm above the minimum receive sensitivity).RF DWN Red (solid) there is a communication problem between the local and remoteTRACERs.Table 3. AUX RS232 PinoutPin Name Source Description1 GND Common Signal ground2 RTS Attached Equipment Request to send (unused)3 TXDATA Attached Equipment Transmit data (from attached equipment)4 DSR TRACER Data set ready5 RXDATA TRACER Received data (to attached equipment)6 CTS TRACER Clear to send7 DTR Attached Equipment Data terminal ready (unused)8 CD TRACER Carrier detectTable 2. TRACER 64x0 LEDs (Continued)For these LEDs... This color light... Indicates that...