Installation36 61287802F1-34BRevision B5. To terminate the 2 Power leads and, and if needed, the 5 alarm status leads, cut wire tolength and strip the insulation back 1/4 inch.6. Loosen each retaining screw and insert the wire into the appropriate slot (see Figure 11on page 34 and Table 7 on page 35).7. Tighten the retaining screws.8. Reinstall the Power/Alarm Connector in the Electronics Module.Figure 14. Power/Alarm Connector Installed9. Tie wrap and route these wires as shown above. This will prevent the connector fromcoming loose when the Electronics Module is closed.5.3.5 Installation of the Power SupplyWARNING!f ■ Before making any power connections to this equipment, verify the power is off (fuseremoved/breaker tripped).■ This equipment should only be operated from the type of certified/listed power supplysupplied by the manufacturer with the equipment.NOTEg When installing the UPS, refer to the UPS manufacturer’s mounting instructions wherepossible.7SIG RTNONT BATREP BATBAT MISLOW BAT12V RTN+12 VDC6 5 4 3 2 1Tie Wrap Wires as shownNote:Even though there are bracketsto position the Power / AlarmConnector wires, their use isnot recommended. Use ofthese brackets can “bind” thewires when the ElectronicsModule is closed.Power / Alarm ConnectorBack of Electronics Module