Using Web Browser AdministrationML700 User Manual 14-252. Select ML Setup.3. Type in the path or use the Browse button to specify the Configuration file that waspreviously saved at a backup location in your PC.4. Click the Download to ML button.5. After the file was successfully downloaded to the ML device it can be restored asexplained in Restore ML Device Backup File (on page 14-25).The Configuration setup file is checked for validity and then downloaded to the system.If the Configuration file is invalid or does not have the same version as the currentlyrunning software, an error message is displayed.Restore ML Device Backup FilePrior to performing the following operations, verify that the ML device backup file issuccessfully downloaded as explained in Download ML Device Backup File. To apply full Configuration setup data This procedure requires opening a Telnet session. Log in to the system and enter thefollowing TL1 command:init-sys:::::restore;The ML device restarts and then operates with the new configuration. To apply provisioning data only (without TID, IP address, Craft port rate and Calibrationdata): Log in to the system and enter the following TL1 command:init-sys:::::duplicate;The ML device restarts and then operates with the new configuration. Continue withconfiguration of the TID, IP address and HSL calibration, if required.Retrieving Logs To access the logs (Command and System Info):1. In the Actelis System Support page, under View / Upload file from ML, type theUsername and Password.