10. Click on the Data Matrix ECC 200 symbology under the Image Settings branch (enabled by default).If this symbology is among those in your application it will be shown in the image display with its code symbologyname. A small green box around it indicates it is decoded.Figure 46. Decoded SymbologyNote: The large green box for each symbol indicates the code localization area which by default isequal to the maximum FOV. Resize and move the box by dragging the borders with the mouse.The code must be found within this area in order to be decoded.11. Add application-specific codes to the Code Settings by selecting them from the icons over the ConfigurationParameters tree area.12. If the Data Matrix symbology is not used, delete it from the Code Settings with the icon.If you don’t know the code type, use the Code Autolearn17 feature by clicking the icon. See the BarcodeManager Instruction Manual for details.13. For each code symbology set the relative parameters according to your application.6.3 Reading Phase1. Click Reading Phase.2. Select your application-specific Operating Mode from the icons over the Configuration Parameters tree area:• Continuous• One Shot• Phase ModeContinuous Mode and Acquisition Trigger are shown by default.3. Configure the relative Operating Mode parameters from the Reading Phase parameters panel.Different groups appear in the panel depending on the selected icons over the Configuration Parameters tree area.17 The Code Autolearn procedure will not recognize the following symbologies: Pharmacode, MSI, Standard 2 of 5, Matrix 2 of 5.ABR 3000 Series Barcode Reader38 www.bannerengineering.com - Tel: + 1 888 373 6767