• Discard After Read—After the last code in the output buffer is read by the EtherNet/IP server manager (host), it isdeleted from the output buffer. In this way it will not be re-read by the same host (or any host) in case of a re-connection.When there is more than one code in the output buffer, the EtherNet/IP protocol requires that each code read by the hostbe deleted and replaced by the next code in the output buffer.8.2.3 ABR Series EDS File Installation in Studio 5000 Logix DesignerSoftwareUse the EDS Hardware Installation Tool to register the Electronic Data Sheet (EDS) file.Use the follow the steps, as well asABR Series Manual Installation in Studio 5000 Logix Designer Software on page 62 toquickly and easily establish an implicit Class 1 connection between the ABR and a Rockwell Studio 5000 Logix Designerfamily PLC. Screenshots are from an example configuration with a ControlLogix 1756-L71 with a 1756-ENBT/A Ethernetmodule, using Studio 5000 Logix Designer version 30.1. Download Banner_ABR_1_1_08312018.eds fromwww.bannergineering.com.2. On the Tools menu, click EDS Hardware Installation Tool.The Rockwell Automation's EDS Wizard dialog displays.Figure 66. Tools—EDS Hardware Installation Tool3. Click Next.4. Select Register an EDS file(s).Figure 67. Rockwell Automation's EDS Wizard—OptionsABR 3000 Series Barcode Readerwww.bannerengineering.com - Tel: + 1 888 373 6767 57