2 Specifications and Requirements2.1 Specifications—ReaderSupply Voltage5 V dc to 30 V dc10 V dc to 30 V dc with TCNM-ACBB1Consumption0.4 A maximum at 5 V dc0.1 A maximum at 30 V dcCommunication InterfaceMain RS232 or RS422 full duplex: 2400 bit/s to 115200 bit/sUSB: USB 2.0 Hi-SpeedEthernet2: 10/100 Mbit/sInputsInput 1 (External Trigger) and Input 2: Protected against short-circuits(opto-isolated, polarity insensitive, and PNP only when connectedthrough TCNM-ACBB1, seeInputs on page 22 for specifications)Maximum voltage: 30 V dcMaximum input current: 3.5 mAOutputs2 NPN/PNP/Push-Pull software selectable, reverse polarity and shortcircuit protected outputs available (2 Opto-isolated outputs instead ifusing TCNM-ACBB1, seeOutputs on page 25 for specifications)Maximum Current: 100 mA maximum continuous or 145 mA pulsedOutput Saturation Voltage (in PNP or NPN mode): < 1.7 V at 100 mAMaximum load device voltage drop (in NPN mode): 30 VOptical FeaturesImage Sensor: CMOS sensor with Global ShutterWVGA 1.2 MPImage Format 752 × 480 1280 × 960Frame Rate 57 frames/second 36 frames/secondFocus Range3Factory calibratedpositions (mm)45 - 70 - 125 45 - 80 - 125Tilt: 0° to 360° within vertical FOVLED Safety: LED emission according to EN 62471Laser Safety (Aiming source): IEC60825-1 2007Lighting System: Internal IlluminatorAiming System: Laser IndicatorConstructionAluminumWeight in grams (ounces)Serial and USB: 117 (4.1) with cableSerial and Ethernet: 200 (7.1) with cableOperating ConditionsOperating Temperature: 0 °C to +45 °C (+32 °F to +113 °F)Storage Temperature: –20 °C to +70 °C (–4 °F to +158 °F)90% maximum relative humidity (non-condensing)Vibration Resistance EN 60068-2-614 mm at 2 to 10 Hz; 1.5 mm at 13 to 55 Hz; 2 a (a), 70 to 500 Hz; 2hours on each axisShock Resistance EN 60068-2-2730 g; 11 ms; 3 shocks up and 3 down on each axisBump Resistance EN 60068-2-2930g; 6 ms; 5000 bumps up and 5000 down on each axisEnvironmental RatingIEC IP65Required Overcurrent ProtectionWARNING: Electrical connections must bemade by qualified personnel in accordancewith local and national electrical codes andregulations.Overcurrent protection is required to be provided by end productapplication per the supplied table.Overcurrent protection may be provided with external fusing or viaCurrent Limiting, Class 2 Power Supply.Supply wiring leads < 24 AWG shall not be spliced.For additional product support, go towww.bannerengineering.com.Supply Wiring (AWG) Required Overcurrent Protection (Amps)20 5.022 3.024 2.026 1.028 0.830 0.5IndicatorsPower LEDReady, Good, Trigger, Com, Status LEDEthernet Network LEDGreen Spot LEDOtherSmart Teach button (configurable via Barcode Manager), beeperCertifications2 The Ethernet interface supports application protocols: TCP/IP, EtherNet/lP, Modbus TCP3 Three factory calibrated positions; continuous focus range for fine tuning4 High ambient temperature applications should use metal mounting bracket for heat dissipation.ABR 3000 Series Barcode Reader6 www.bannerengineering.com - Tel: + 1 888 373 6767