Rated SensingDistanceSet DistanceSensingSurfaceSensingObjectHysteresis (Differential Travel)—With respect to the distance between the standard sensing object and the sensor, thedifference between the distance at which the sensor operates and the distance at which the sensor resets.SensingDistanceResetDistanceSensingObjectOFF ONHysteresisNote: Smaller hysteresis values cause the output to switch state with less differential travel. A largerhysteresis value makes the output state to remain unchanged with larger differential travel. Negativehysteresis values allow the operator to move the hysteresis to either side of the switch point.3.2.9 Zero Reference LocationUse this menu to select the zero reference location. Changing the zero reference location only affects the readout on thedisplay and does not affect the output. The default is , 0 = the front of the sensor. This menu is not available in dual(intensity + distance) mode.• —0 = the front of the sensor; the measurement increases further from the sensor• —0 = maximum range; the measurement increases closer to the sensor3.2.10 Shift the Zero Reference Location after a TEACHUse this menu to select whether the sensor shifts the zero reference location based on the last TEACH process. The defaultis , 0 = the front of the sensor or the maximum range. This menu is not available in dual (intensity + distance) mode.• —Shift the zero reference location to one of the taught positions with each TEACHQ5X Laser Triangulation Sensor with Background Suppressionwww.bannerengineering.com - Tel: +1.763.544.3164 15