The taught surface must be inside of the defined sensing range. When the teach mode is set to FGS, some portion of thewindow must be located within the sensing range. When the teach mode is set to BGS, the offset value must be within thedefined sensing range. If an offset value falls outside of the sensing range, a message displays. See the applicable TEACHprocedure for more information.3.2.12 Display ViewUse this menu to select the display view. The default is right-reading.• —Right-reading• —Inverted• —Right-reading and the display enters sleep mode after 60 seconds• —Inverted and the display enters sleep mode after 60 secondsWhen the sensor is in sleep mode, the display wakes with the first button press.3.2.13 UnitsUse this menu to set the displayed units to centimeters (cm) or inches (").• —centimeter (with a decimal point at < 60 centimeters)• —inch (with a decimal point at < 24 inches)3.2.14 Output Type PolarityUse this menu to select the output polarity.• (Default)—Push-Pull IO-Link on pin 4 and solid state PNP on pin 2• —Solid state PNP on pins 2 and 4• —Solid state NPN on pins 2 and 43.2.15 Exit Setup ModeNavigate to and press SELECT to exit Setup mode and return to Run mode.3.2.16 Reset to Factory DefaultsUse this menu to restore the sensor to the factory default settings.Select to return to the sensor menu without restoring the defaults. Select to apply the factory defaults andreturn to Run mode.Factory Default SettingsSetting Factory DefaultDelay Timers ( ) —No delayDisplay View ( ) —Right-reading, no sleep modeGain and Sensitivity ( ) —High excess gain modeOutput ( , ) —Light OperateResponse Speed ( ) —25 msShift the Zero Reference Location after a TEACH ( ) —0 = the front of the sensorQ5X Laser Triangulation Sensor with Background Suppressionwww.bannerengineering.com - Tel: +1.763.544.3164 17