4. Present the target.Method Action ResultPush ButtonPresent the second target. The sensor-to-target distance must be within thesensor's range., , and the distancemeasurement flash alternately on thedisplay. The DYN, FGS, and BGSindicators flash.Remote Input5. Teach the sensor.Method Action ResultPush Button Press TEACH to teach the target.The new switch point flashes rapidly andthe sensor returns to Run mode.Remote Input Single-pulse the remote input. TTable 2: Expected TEACH Behavior for Two-Point Static Background SuppressionSeeFigure 24 on page 33 for the minimum object separation.Condition TEACH Result DisplayTwo valid distances that are greater than orequal to the horizontal minimum objectseparationSets a switch point between the two taught distances. The switch point distance flashes on thedisplay.Two valid distances that are less than thehorizontal minimum object separationSets a switch point in front of the furthest taught distanceby the horizontal minimum object separation. and the switch point distance flashalternately on the display.One valid distance with one invalid TEACHpointSets a switch point between the one taught distance andthe maximum range. and the switch point distance flashalternately on the display.Two invalid TEACH points Sets a switch point for the currently selected channel at200 cm. and the switch point distance flashalternately on the display.3.6.2 Dynamic Background SuppressionDynamic TEACH sets a single switch point during machine run conditions. Dynamic TEACH is recommended forapplications where a machine or process may not be stopped for teaching. The sensor takes multiple samples and theswitch point is set between the minimum and the maximum sampled distances.SwitchPointValue14Press to startsamplingPress to stopsampling2Press andHold > 2s3 5Figure 21. Dynamic Background SuppressionNote: The sensor must be set to = to use the following instructions. The DYN indicator isamber to indicate Dynamic TEACH mode.Q5X Laser Triangulation Sensor with Background Suppression22 www.bannerengineering.com - Tel: +1.763.544.3164