3.4.2 Reset to Factory Defaults Using the Remote InputEight-pulse the remote input to apply the factory defaults and return to Run mode.TTTTTTTTTTTT TTTNote: The input wire function remains at remote teach input ( ).3.5 Locking and Unlocking the Sensor ButtonsUse the lock and unlock feature to prevent unauthorized or accidental programming changes. Three settings are available:• —The sensor is unlocked and all settings can be modified (default).• — The sensor is locked and no changes can be made.• —The switch point value can be changed by teaching or manual adjustment, but no sensor settings can bechanged through the menu.Note: When the sensor is in either or mode, the active channel can be changed using (+)(CH1/CH2).When in mode, displays when the (SELECT)(TEACH) button is pressed. The switch point displays when (+)(CH1/CH2) or (-)(MODE) are pressed, but displays if the buttons are pressed and held.When in mode, displays when (-)(MODE) is pressed and held. To access the manual adjust options, brieflypress and release (+)(CH1/CH2) or (-)(MODE). To enter TEACH mode, press the (SELECT)(TEACH) button and hold forlonger than 2 seconds.Button InstructionsTo enter mode, hold and press four times. To enter mode, hold and press seven times.Holding and pressing four times unlocks the sensor from either lock mode and the sensor displays .Remote Input Instructions1. Access the remote input.Action ResultFour-pulse the remote input.T TT T TT T The sensor is ready to have the button statedefined and displays.2. Lock or unlock the sensor buttons.Action ResultSingle-pulse the remote input to unlock the sensor. T displays and the sensor returns toRun mode.Double-pulse the remote input to lock the sensor.T TTdisplays and the sensor returns toRun mode.Triple-pulse the remote input to apply the operatorlock to the sensorT TTTTdisplays and the sensor returns toRun modeQ5X Laser Triangulation Sensor with Background Suppression20 www.bannerengineering.com - Tel: +1.763.544.3164