en_BA_OxE7_PosCon3D.docx 22/64 Baumer Electric AG17.07.2014 14:21/tof V1.01 ANW_81125407 Frauenfeld, Switzerland5 Configuration via touch panel5.1 Overview of control elements5.1.1 Display modesRun modeThe sensor is in run mode, the measuring value isdisplayed in large characters.Main menuIn the main menu the active measuring type is displayed atthe top, and the measuring value is displayed at thebottom.Scroll barThe square indicates the position within the current menu.The next menu item can be accessed using the arrowkeys.Change valueIf the function/mode at the top is displayed on a blackbackground, the value of the bottom line can be adjustedusing the UP/DOWN keys and saved using SET.Process successfulThe display background lights up green: valuesuccessfully savedErrorThe display background lights up red: Error during thesave process or wrong value entered.Setting modeWhen the sensor is in setting mode, the display backlightlights up blue.Keys lockedIf this symbol is on the left side of the screen, the four keysare locked for operation.FLEX MOUNT activeWhen FLEX MOUNT is activated, this angle symbolappears on the left side of the screen.Rectangle field activeThis symbol appears on the left side of the screen whenthe measuring field is rectangular (AUTO).LEDsTouch panel: Fourtouch-sensitive keysESC UP DOWN SETGraphicaldisplay